Tuesday, April 10, 2012

[MW:14088] Max allowable offset

Dear experts,  I have a question. For circumferencial joint joining two thicknesses for a pressure vessel  e.g. 8 mm and 10.5 mm what is maximum allowable offset ?  As per uw 33 it comes out to be 2 mm .my question is it can not be tapered transition as the thk difference is less than 3 mm as per uw 9.  Now if we match ID then the offset will be 2.5 mm and we can not taper the joints also.  Please suggest.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34919] Welder qualification certificate

Dear All     anyone can share a format for welder certificate and card format        Thanks & Best Regards Saleem manhappulath Mob:+9665...