as per section 9, there is no restriction, but in construction code
like section 8,UCS in repair welding it weaving width is restricted
4Xcore dia of smaw electrode. it is good engineering practice to
restric weaving width to reduce heat input, and welder fatigue
Pandithan
Cethar limited

On 4/11/12, Mohit Aggarwal <aggarwalmohit05@gmail.com> wrote:
> Respected Experts,
>
>
> We generally mention in WPS/PQR weaving of Electrode should be *three
> times*the Electrode dia...I have query is Code restrict for this
> ,anywhere
> written in code aur it is on general experience...
>
>
> Thanks & Regards
> Mohit Aggarwal
>

--