Tuesday, April 3, 2012

[MW:14044] crack in weld during fillet welding in E-450 grade plate

Dear experts,

 

Please suggest the welding procedure and welding parameters to weld E-450 grade steel plate through saw wire (EA-2) and flux (agglomerated-F8A2-EA2-A2).

 

Also, please find here with the attachment of joint details and plate test certificate for your ready references.

 

Because, we are facing the problem of weld cracks in patches during 9 mtr continue fillet welding.

 

If you need any more details please write to us.

 

T&R

PT

 

 

 

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...