| Dear Nilesh, Please see attached some literature on the subject. In short, you are required to work within the PQR established heat input values. No more, no less. I know in Shell DEP, there is some reference to it, but this literature explains it better. Hope it helps. Best regards, Shashank Vagal --- On Sun, 1/4/12, waman nilesh <wamannp@gmail.com> wrote:
|
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.