If you read the full para (5.7.8.11) carefully, you can clearly differentiate RT on nozzle Long. seams is required or not without any confusion.
Regards
Ramu
--- On Wed, 2/7/08, Bathula Raghuram (Mumbai - PIPING) <R.Bathula@ticb.com> wrote:
> From: Bathula Raghuram (Mumbai - PIPING) <R.Bathula@ticb.com>
> Subject: [MW:888] %RT on nozzle long seam per API650
> To: materials-welding@googlegroups.com
> Date: Wednesday, 2 July, 2008, 4:31 PM
> Ref: API650 2007 edition
>
>
>
> Para 5.7.8.11 states 'All longitudinal butt-welds in
> the nozzle neck
> etc..............shall receive 100% radiographic
> examination (see 8.1)
>
> Where as in para 8.1.1 states 'Radiographic inspection
> is not required
> for the following:............welds in nozzle and man way
> necks made
> from plate'
>
>
>
> Which one is correct or am I not interpreting correctly?
>
>
>
> Note: if you are referring old editions it is same (just
> refer para
> 3.7.8.11 and 6.1.1 instead of the above)
>
>
>
Meet people who discuss and share your passions. Go to http://in.promos.yahoo.com/groups/bestofyahoo/
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---