6010 is high penetration electrode. Root gap shall be 1-1.5mm. Otherwise undercut will come.
2008/7/22 atul patil <atulpatil99@gmail.com>:
Dear allI am working with Gas export pieline in KazakhstanWe are using 6010 electrode for root& 8010 for fill capwe are facing the problem with root undercutActually on the basis of radiography ( ISO 13847 ) doesnt ask to cmpareason of density with parent metal It says only about lengthPlease guideIt is very difficult to prepare the calibration block for UT ( Manual ) in my city ( Atyrau )Could you please guideany suggestions welcome.
--
Thanks & Regards
Muhammed Ibrahim PK
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---