Tuesday, July 22, 2008

[MW:956] Root under cut

Dear all
I am working with Gas export pieline in Kazakhstan
We are using 6010 electrode for root
& 8010 for fill cap
 
we are facing the problem with root undercut
 
Actually on the basis of radiography ( ISO 13847 ) doesnt ask to cmpareason of density with parent metal It says only about length
 
Please guide
It is very difficult to prepare the calibration block for UT ( Manual ) in my city ( Atyrau )
Could you please guide
any  suggestions welcome.

--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...