[MW:917] HARDNESS REQUIREMENT FOR SA333GR6 PIPE

DEAR MEMBERS,

 

I AM SHAILESH WORKING AS A QA/QC INCHARGE CORE TEAM MEMBER ADGAS, DAS ISLAND. WE ARE WORKING HERE FOR THE FORTHCOMING MAJOR SHUTDOWN.

 

IN ONE OF THE REPAIR & RECOMANDATION I CAME ACROSS AN INTERESTING CASE.

 

ONE 20" Sch. 10 SYSTEM HAS COME UNDER SECTIONAL REPLACEMENT. MATERIAL IS SA333 GR.6 ERW PIPE. CLIENT IS ASKING FOR HARDNESS MAX. 200 BHN. ALSO THRE IS NO PWHT INVOLVED IN IT.  CLIENT HAS NOT CLARIFIED IF THIS HARDNESS IS AFTER WELDING OR AS RECEIVED MATERIAL. I HAVE REFERED THE ASME SEC. II PART A WHERE SA333 GR.6 DO NOT ASK FOR ANY HARDNESS.

 

I WANT TO KNOW FROM YOU MEMBERS WHAT IS THE HARDNESS OF SA 333 GR.6 IN AS RECEICED CONDITION. WHAT WOULD BE HARDNESS AFTER WELDING.

 

REGARDS,

 

SHAILESH

 

UAE - DAS ISLAND



--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...