Sunday, July 27, 2008

[MW:973] Re: Root under cut

Dear Atul
 
Ar you looking for information How to avoid root undercut or NDT method to analisied under cut in most sensitive manner?
 
please give further information.
 
Regards
 
Paresh Katvi

 
On 7/22/08, atul patil <atulpatil99@gmail.com> wrote:
Dear all
I am working with Gas export pieline in Kazakhstan
We are using 6010 electrode for root
& 8010 for fill cap
 
we are facing the problem with root undercut
 
Actually on the basis of radiography ( ISO 13847 ) doesnt ask to cmpareason of density with parent metal It says only about length
 
Please guide
It is very difficult to prepare the calibration block for UT ( Manual ) in my city ( Atyrau )
Could you please guide
any  suggestions welcome.
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...