Monday, July 4, 2022

Re: [MW:33199] Hydro Test Pressure difference_ Piping Spool's

Hi,
Test is acceptable as the highest point is witnessed for the required pressure, however please cross check once again for the difference in the highest level to the lowest level  and the difference in pressure in terms of Mtr of H2O

Thanks & Regards,
Lakshman kumar B
+91 9440031459.


On Sat, 2 Jul 2022 at 19:50, Manikandan J <mechmani22@gmail.com> wrote:
Dear All,

We have conducted a hydro test of Piping Spools (14'' Pipe x 12 Mtr Long),we have  faced Gauge pressure difference at Higher and lower end.

Test Pressure Required : 283 PSIG

Lower End  : 290 PSIG
Higher End : 283 PSIG

Kindly provide what is acceptable pressure difference between lower and higher end.

Regards,
Pradeepan.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAPdGVmOG_p74j5MnzJ0ELbmDWCa7gnB0e2%2B13KP1B7TTv3EKdA%40mail.gmail.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAO-dY%3Dha8-EfhOGkq0%3DEB3oZih%2BcXf86ogYzt8iWXpt1%2B0hshA%40mail.gmail.com.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...