Take minimum and maximum among the reading recorded
On Sun, 31 Mar 2019 8:04 am Gowtham Rajendran, <rajgowthamiwe@gmail.com> wrote:
--I.e Heat Input is different in various layers for the fillup passes.On Sat, 30 Mar 2019 at 18:01, Gowtham Rajendran <rajgowthamiwe@gmail.com> wrote:Hi ,A very good evening to you all.My doubt is in establishing the heat input for multipass welding , (root , fill & cap) , for the fillup passes my parameters are different for different layers , which one should i consider for establishing the Heat Input because in this CVN Requirement apply & the heat input cannot be increased as per the code (Be it ASME Sec IX or AWS D1.1).How to solve this problem? Kindly help.Regards,Gowtham.
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.
No comments:
Post a Comment