Saturday, March 23, 2019

[MW:29360] Re: RT Sensitivity Not Achieving for Pipe 1 1/2 " Sch 40

Dear Vikram,

May i know what is the IQI you are using?

On Monday, March 18, 2019 at 6:54:57 PM UTC+3, Vikram Saipogu wrote:
Dear All,

Please provide me some suggestion,

How shall I achieve sensitivity for lower thickness and lower diameter pipe using Gamma Rays i.e Iridium 192 ?

Client requirements is Radiography by Gamma Rays 

Thanking you


Best Regards,

Vikram Saipogu


--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:35507] WPS for Furnace PWHT

As per ASME B31.3, Clause 331.1.6 (b): Any required PWHT shall be carried out in accordance with the qualified WPS. For furnace PWHT inv...