Dear it is not acceptable at all. Pl ask for the required standard and Specs which is valid as per the B31.1.
Peter
Welding Eng.
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Jayasuryan Raveendran
Sent: Thursday, August 06, 2015 2:36 PM
To: materials-welding@googlegroups.com
Subject: [MW:23278] blind welded to pipe at test limit
Dear frnds
For hydro test limit contractor does not have any blind flange or end caps so contractor requesting to diectly weld blind to the pipe. Is it acceptable. Any references for that. Constrtion code b31.3 test pressure 44 kgf per cm square
Regards
Jayasuryan
--