Our client spec. requires 5Cr material with thickness more than 10mm requires dehydrogenition heat treatmnet
-- But the contractor has welded and immediately completed PWHT without going for DHT, Is that acceptable
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/6c6af4e1-2a5b-4a8f-9aab-993accc61023%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.