You have to look in your design code for this. You will find this info neither in ASME IX nor in A312

    best regards

    Dr. Georgios Dilintas

    Authorized Nuclear Inspector
    Authorized Inspector Supervisor
    API 510 Inspector

    I&F REGIONAL TECHNICAL MANAGER
    BUREAU VERITAS HELLAS

    Tel: +30 210 40 63 113/4
    Fax: +30 210 40 63 118
    Cell: +30 69 44 64 62 04
    (See attached file: Dilintas_George.vcf)

Anurudh Choudhary ---14/03/2014 15:00:23---Dear All, I'm using A312 TP304 pipe for design temperature -(minus) 196 degC for BOIL

From: Anurudh Choudhary <theoilgasengineer@gmail.com>
To: materials-welding@googlegroups.com
Date: 14/03/2014 15:00
Subject: [MW:20323] Acceptable Values for Charpy Impact Test at -(minus) 196 degC for A312 TP304
Sent by: materials-welding@googlegroups.com




Dear All,

I'm using A312 TP304 pipe for design temperature -(minus) 196 degC for BOIL OFF GAS (BOG) service.

we have carried out the charpy impact test at -(minus) 196 degC for the pipe. we are having average value of Joules for pipe specimens.

Please provide/guide me with the Acceptable value for Charpy impact values( Joules) at -(minus) 196 degC along with codes/reference for A312 TP304 Pipe.

Kind Regards,

Choudhary Anurudh

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm

The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to
materials-welding+unsubscribe@googlegroups.com.
For more options, visit
https://groups.google.com/d/optout.

This message contains confidential information. To know more, please click on the following link: http://disclaimer.bureauveritas.com

No comments:

[MW:34919] Welder qualification certificate

Dear All     anyone can share a format for welder certificate and card format        Thanks & Best Regards Saleem manhappulath Mob:+9665...