You have to look in your design code for this. You will find this info neither in ASME IX nor in A312
- best regards
Dr. Georgios Dilintas
Authorized Nuclear Inspector
Authorized Inspector Supervisor
API 510 Inspector
I&F REGIONAL TECHNICAL MANAGER
BUREAU VERITAS HELLAS
Tel: +30 210 40 63 113/4
Fax: +30 210 40 63 118
Cell: +30 69 44 64 62 04
(See attached file: Dilintas_George.vcf)
Anurudh Choudhary ---14/03/2014 15:00:23---Dear All, I'm using A312 TP304 pipe for design temperature -(minus) 196 degC for BOIL
From: Anurudh Choudhary <theoilgasengineer@gmail.com>
To: materials-welding@googlegroups.com
Date: 14/03/2014 15:00
Subject: [MW:20323] Acceptable Values for Charpy Impact Test at -(minus) 196 degC for A312 TP304
Sent by: materials-welding@googlegroups.com
Dear All,
I'm using A312 TP304 pipe for design temperature -(minus) 196 degC for BOIL OFF GAS (BOG) service.
we have carried out the charpy impact test at -(minus) 196 degC for the pipe. we are having average value of Joules for pipe specimens.
Please provide/guide me with the Acceptable value for Charpy impact values( Joules) at -(minus) 196 degC along with codes/reference for A312 TP304 Pipe.
Kind Regards,
Choudhary Anurudh
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/d/optout.