Dear sir
ASME SEC-I ,PW-39
-- ASME SEC-I ,PW-39
2)when the nominal thickness of a weld as defined in PW-39.4 is greater than % in. (19 mm) but does not exceed 1 % in. (38 mm), and:
(a) the calculated carbon equivalent, CE, of any of the basemetals in the weld joint is less than or equal to 0.45, using the formula :
CE = C + (Mn + Si)/6 + (Cr + Mo v)/S + (Ni + CU)/15
Can I use above clause of ASME SEC-I ,PW-39 to following welding to eliminate the PWHT of membrane panel header
- Item : Membrane Panel
- Material : SA106 Gr B and SA210 Gr A1
- OD and thk : 273 *35 header,panel tube : 50.8*6.35 thk
- Joint type : Groove +Fillet
- Weld deposition : 12 mm
- No of Tube : 35 nos
- CE : less than 0.45
- preheat : 100 deg C
- boiler type : CFBC
plz suggest
Regards
Rajesh S Mhaske
Engineer Welding,CSWIP3.1,ASNT Level-II
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/d/optout.
No comments: