Dear,
please API 653 Appendix b 3.3,
your Bb value is 20mm so 20/0.37=54mm shoulb be your bulged circle radii.
Bb= 0.37R.
regards
mohd.
On Monday, November 18, 2013 7:17:28 AM UTC, golden wrote:
Dear allI have 3 naoh dosing & storage tank ,after water fill up test i foud bulged 15 to 25 mm in bottom plate Tanks Details BelowThk-6mmBottom Plate diametr-2560,over all length-3400material grade-SA240-TP316LAs per API 650 Please provide me acceptable limit with code referenceI am very grateful for all this.--
Best Regards,
Raghib Ali
QA/QC InspectorMobile: +971 55 5865648
Lamprell Energy Ltd
PO Box 42149, Port Khalid, Sharjah, United Arab Emirates.
Tel: +971 6 528 5345 | Fax: +971 6 528 5820
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.
Comments