Tuesday, November 26, 2013

Re: [MW:19367] Re: API 650 RT repair %

Dear,
You are lucky that this % is based on length and not joints.
General repair % action criteria is this: 
< 1% Tolerable
Up to 1.5% Caution level
1.5 -2.5% Welder needs to be warned
>2.5% Welder to be withdrawn from job and sent for practice
 
With Best Regards,
Shashank C Vagal


On Monday, 25 November 2013 10:42 AM, mohd <mohd52100@gmail.com> wrote:

Sunil,

No need to worry abour porosity or TI..length of repair how much they excavate for repair.is it clear

take welder wise length of welder welded divided by length of repair of that welder.

Length wise repair is best way to avoid confusion between plates and pipe welding by welders.

Rejection rate/repair allowed is defiantly mentioned in your project spec.


regards,
mohd.


On Sunday, November 24, 2013 11:55:36 AM UTC, sunilkumar kundothara wrote:
Dear All,

Kindly share infos about the weld repair percenatge / rejection rate
with respect to API 650 tank construction. sub-con is calculating on
the basis of repair length divided by total weld length. but the
repairs amy be porosity, tungsten inclusion or other rounded
indications as the case may be. in such cases how we could calculate
the length exactly. also please share why it is not possible by
individual welders too (or how their % can be calculated). i beleive
it is not mentioned by 650.
Thanks in advance,
Kumar
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.