Dear Expert,
Delvery Condition is Normalized
Heat No. & Lot No. is same
Qty. 4 Nos.
Weight:1500 Kg / Forging
How many testing is required as per Section II P-A?
8.2.1.1 For forgings weighing 5000 lb [2250 kg]
or less at the time of heat treatment, one tension test shall
be taken from one forging per heat in each heat–treatment
charge. When heat treatment is performed in continuoustype
furnaces with suitable temperature controls and
equipped with recording pyrometers so that complete heattreatment
records are available, a tempering charge may
be considered as any continuous run not exceeding an 8 h
period.
8.2.1.2 For forgings and forged bars weighing over
5000 lb [2250 kg] at the time of heat treatment, one tension
test shall be taken from each forging.
Regards,
Ankit Gandhi
-- Delvery Condition is Normalized
Heat No. & Lot No. is same
Qty. 4 Nos.
Weight:1500 Kg / Forging
How many testing is required as per Section II P-A?
8.2.1.1 For forgings weighing 5000 lb [2250 kg]
or less at the time of heat treatment, one tension test shall
be taken from one forging per heat in each heat–treatment
charge. When heat treatment is performed in continuoustype
furnaces with suitable temperature controls and
equipped with recording pyrometers so that complete heattreatment
records are available, a tempering charge may
be considered as any continuous run not exceeding an 8 h
period.
8.2.1.2 For forgings and forged bars weighing over
5000 lb [2250 kg] at the time of heat treatment, one tension
test shall be taken from each forging.
Regards,
Ankit Gandhi
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.
Comments