Thursday, January 19, 2012

Re: [MW:13517] amendment for this WPS regarding

Dear All,
You can make a new wps with the preheat require as far as your pqr allowed that + or - 55
Regards
Paul
Sent via my BlackBerry from Vodacom - let your email find you!

From: "venkateswaran k" <kvnkat@rediffmail.com>
Sender: materials-welding@googlegroups.com
Date: 12 Jan 2012 08:25:07 -0000
To: <materials-welding@googlegroups.com>
ReplyTo: materials-welding@googlegroups.com
Subject: [MW:13460] amendment for this WPS regarding

Dear All,

We qualified WPS for Material SA 516(P:1,G:1) TO SA240TP 316L(P:8,G:1) by SMAW process as per ASME Sec IX ,thickness range- base metal Grove is: 5 -30 mm,Filler metal:E309 Mol.

My question is while qualifying we did not mentioned Preheating and Inter pass temperature (in WPS -QW 406),now one of our client asking for these two parameters need to be filled /required, in this case how to convince him. Whether can I make amendment for this WPS, it is acceptable as per ASME Sec IX. If yes can u provide format for this amendment.

kvr
Follow Rediff Deal ho jaye! to get exciting offers in your city everyday.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34866] Presentation for WPS ,PQR AND WPQ as per ASME Sec IX in power point

Dear Experts.        If anyone having presentation of WPS,PQR and WPQ  as per ASME  SEC.IX  in power point then please share . Regards Sanja...