yes, additional tests and record can be added to an original PQR at a
later date, provided essential and supplementary essential variables,
when applicable, is not changed.
Rgds
2012/1/15, rinshu <rinshad043@gmail.com>:
> Dear All,
>
> We have a PQR in which we did all the mechanical testing as per the
> requirement of Sec IX.We would like to add some additional hardness
> and impact test result to the same PQR.I have referred the code Para.
> QW-200.2 which states that
>
> "additional information can be incorporated into a PQR at a later
> date provided the information is substantiated as having been of the
> original qualification condition by lab record or similar data"
>
> Can anyone tell me what are the documents to be added to the original
> PQR to satisfy the code requirement.
>
>
> Rins.
>
> --
> To post to this group, send email to materials-welding@googlegroups.com
> To unsubscribe from this group, send email to
> materials-welding+unsubscribe@googlegroups.com
> For more options, visit this group's bolg at
> http://materials-welding.blogspot.com/
> The views expressed/exchnaged in this group are members personel views and
> meant for educational purposes only, Users must take their own decisions
> w.r.t. applicable code/standard/contract documents.
>
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/