Please give the detail of the applicable code and whether Impact test is required based on MDMT
Thanks & Regards J.Gerald Jayakumar 0091-9344954677
From: manoj john <manojacgnr@gmail.com>
To: materials-welding@googlegroups.com
Sent: Saturday, January 21, 2012 7:55 PM
Subject: [MW:13536] REGARDING PWHT of STORAGE TANK CLEAN OUT DOOR.
Dear All,
-- I intended to use the following WPS for storage tank clean out door welding :
Test coupon thickness - 40 mm.
Material - SA 516 Gr 70
Welding process - SMAW.
Electrode - E 7018-1
PWHT Temperature - 620 - 650 degree centigrade.
Soaking time - 180 minutes.
Rate of heating - 130 Degree centigrade.
Rate of heating - 130 Degree centigrade.
Storage tank detail:
Shell thickness - 18 mm
Annular plate thickness - 20 mm
Clean out door neck - 18 mm
Clean out door flange - 20 mm
Material - SA 516 Gr 70
Welding process - SMAW
Electrode - E 7018 -1
Stress relieving temp - 620 - 650 degree centigrade.
Soaking time - 60 minutes.
Rate of heating - 150 - 200 Degree centigrade.
Rate of heating - 150 - 200 Degree centigrade
My doubt is whether the soaking time in the PQR is acceptable or I have to qualify another WPS.
Thanks in advance.
Manoj
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
No comments:
Post a Comment