Hello Jignesh,
What's the standard to be followed for SSCC testing.
Appreciate your reply.
Thanks.
Pradip Goswami,P.Eng.IWE
Welding & Metallurgical Specialist & Consultant
Ontario,Canada.
Email-pgoswami@sympatico.ca,
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Desai Jignesh (Mumbai - Piping)
Sent: Thursday, January 12, 2012 10:19 PM
To: materials-welding@googlegroups.com
Subject: [MW:13463] SSCC testing
Hi,
For sulphide stress corrosion cracking of any material at high temp and 90 bar pressure if 0.005 mole % H2S is required, is the test same if pressure is reduced to 60 bar and mole% H2S is increased to obtain same partial pressure. i.e, if we increase mole % H2S and decrease total pressure, is the test condition remain same or alter?
Regds/Jignesh
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.