For Drying is only for control of Hydrogen induced crack in the weld metal , For that only Low hydrogen electrodes are to be Baked & Dried. It will not affect the Chem & Mech properties.
175, R.Kesavamoorthi,
Principal surveyor,
Quest (pvt.) Ltd.,
Ranipet.
From: asad azmi <azmiasadayub@gmail.com>
To: materials-welding@googlegroups.com
Sent: Sun, 26 September, 2010 9:38:22 AM
Subject: [MW:7196] use of E 7018 Electrode for stuructural welding without proper drying and holding
Dear All,
Goodday.
what will be the effect in Mechanical/chemical proerties of deposited weld metal of E7018 which is used for Structural welding of angle bar( material CS) without drying (at 260-430deg C) and Holinding(at 120 deg C).
Can E7018 be used without proper drying and holding for stuructural welding( fillet weld only) of angle bar/supports(material CS).
Thanks in advance for your valuable suggestions.
Best Regards
Asad Azmi
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.