PWHT is mandatory by code for that thickness.

On Sep 29, 9:16 pm, "sunilrathor...@yahoo.com"
<sunilrathor...@yahoo.com> wrote:
> Dear member,
>
> We have an pipe made from sa 672 cl 22 mat having dia 72" and thk 22 mm used for flair line in refinery. The construction people are taking devation not to do pwht on basis that they will check the hardness value if it comes under limets they will not do pwht.
>
> i want to know that is hardness testing is substitute for avoiding sr or pwht
> .
> Its design base is asme 31.3
> n Patel
Worley Parsons, London

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...