Re: [MW:3935] RE: 3925] Filler metal SS316 to ASTM A106 Gr.B


Hi Vasanth,
 
We have specially ordered material of ASTM A106 Gr.B at -40 Deg Cel.
 
More over, -40 is the max temp may encountered otherwise the normal working temp is only -20 deg cel in my case.
 
Regards,
 
K.Babu
 
 
On Thu, Dec 31, 2009 at 3:51 PM, Chandra, Vasanthan (Lagos) <Vasanthan.Chandra@deltaafrik.com> wrote:

You can use E309Mo but ensure that A106 Gr B application at -40 Deg.C when impact is required (CS HAZ and CS BM side.) Why don't you consider SA 333 Gr 6?

 

Regards,
Vasanth


From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of babu k
Sent: 30 December 2009 16:28
To: materials-welding@googlegroups.com
Subject: [MW:3925] Filler metal SS316 to ASTM A106 Gr.B

 

Hi gents,

 

On the basis of  metallurgical point of view, is there any effect of choosing E309Mo as the filler metal for the above combination of base metal.

 

Service temp is minus 40 (Max.) 

 

Regards,

 

K.Babu,

Singapore 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.


*** WORLEYPARSONS GROUP NOTICE *** "This email is confidential. If you are not the intended recipient, you must not disclose or use the information contained in it. If you have received this email in error, please notify us immediately by return email and delete the email and any attachments. Any personal views or opinions expressed by the writer may not necessarily reflect the views or opinions of any company in the WorleyParsons Group of Companies."

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



--

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34820] RE: 34813] Clarification in Rate of heating and cooling.

Hello,   Please see the response below.   Regards.   P. Goswami, P. Eng, IWE.   From: materials-welding@googlegroups.com <materials-weld...