Wednesday, December 30, 2009

[MW:3916] the substitute NDT

I have material with 80mm thickness and it's known that RT is not applicable for application as NDT, so what is the substitute method for NDT and please give me the code case number for that?

Note1: the applied code ia ASME VIII Div II

Note2: If the substitute NDT is UT with permanent record but also it's difficult to get it what is substitute to get NDT with permanent record????

 

Eng/Mostafa Kamel

Senior Welding Engineer

SIEMENS

+20104410009


No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...