Skip to main content

FW: [MW:3876] root cause analysis

 

Mr Jalal,

 

The explanations of  Dr Beldyk  are  great and nicely explains the mechanisms of intergranular corrosion in the welds/HAZ  due to sensitization. One of the popular choice avoid sensitization in austenitic S.S is to use stabilized grades such as   316-316L, 321 or 347.

 

321 S.S (Titanium stabilized)  is  prone to one type of intergranular attack known as Knife-Line Attack. The attached document illustrates the form of attack. Normally Knife-Line attack takes   place in presence of very corrosive media such Nitric acids, fuming sulfuric acid or hydrofluoric acids.

 

During welding stabilized carbides ( TiC) dissolve at elevated temperature in and around the fusion line. Upon cooling Cr-carbide will form faster than TiC. This is so because   321 S.S contains 18% Cr as against 0.6-0.8%  of Ti.

 

Should it happen, there would be a thin layer of Cr-carbide depleted zone running along the Weld fusion line in the HAZ and which would corrode once exposed to corrosive media such as nitric acid.

 

In the present context if you could organize a replication of the damaged area, followed by metallurgical analysis, the root cause investigation would be more meaningful.

 

As the severity of corrosion is more during shut down , alkaline washing prior to shutdown might be helpful.

 

The remedial measure would be to selectively weld build up the affected areas with welding electrodes of matching or superior chemistry, with very controlled heat input.

 

Good fabrication practices mentioned below could be useful for  Newer  equipments-

 

§           Base metal chemistry (especially C) should be should be strictly controlled. The maximum limit of "C" is 0.08%, values lower than this would be better.

§           The base metal shall be properly solution annealed as per the applicable material spec, say ASME Sec-II Part C.

§           Preferably get the base metal tested for intergranular corrosion testing, to ASTM 262 Practice-C (Huey Test), welding consumables and on weld coupons during procedure qualification.

§           Take the best possible precautions during welding, control of heat input, MAX interpass temperature of 1750C maximum.

§           Stabilize anneal @ 850-9000C for 2/4 hrs after fabrication so as to allow precipitation of TiC.

§           NACE RP-170-2004, Protection of Austenitic Stainless Steels and Other Austenitic Alloys from Polythionic Acid Stress Corrosion Cracking During Shutdown of Refinery Equipment) provides detailed guidelines for on merits of stabilizing anneal for improved corrosion resistance)

 

Thanks

 

Pradip Goswami,P.Eng

Senior Engineer/Specialist(Welding-Metallurgy)

Machine Dynamics & Component Integrity Dept.

Engineering & Training Services Division

ONTARIO POWER GENERATION Inc.

PO Box-2000, RR-55(South)

Nanticoke, Ontario,N0A1L0

Tel:-(519) 587-2201, Ext 3107--in Nanticoke

         (416) 231-4111, Ext 5925--in Kipling,Toronto

Fax: (519) 587-6814

Email-pradip.goswami@opg.com.

 

-----Original Message-----
From:
pgoswami@sympatico.ca [mailto:pgoswami@sympatico.ca]
Sent:
Tuesday, December 22, 2009 11:08 AM
To:
GOSWAMI Pradip -FOSSIL
Subject: FW: [MW:3874] root cause analysis

 


 
> From: welding_engr_rich@charter.net
> To:
materials-welding@googlegroups.com
> Subject: RE: [MW:3874] root cause analysis
> Date:
Tue, 22 Dec 2009 08:49:25 -0500
>
> Without looking at the problems this is an educated guess... Weld-line
> decay though I would not eliminate an erosion-corrosion process.
>
> ________________________
>
>
> Weld decay is a form of intergranular corrosion, usually of stainless
> steels or certain nickel-base alloys, that occurs as the result of
> sensitization in the heat-affected zone during the welding operation.
>
> The corrosive attack is restricted to the heat affected zone (
HAZ).
> Positive identification of this type of corrosion usually requires
> microstructure examination under a microscopy although sometimes it is
> possible to visually recognize weld decay if parallel lines are already
> formed in the heat affected zone along the weld.
>
>
>
> Cause? As in the case of intergranular corrosion, grain boundary
> precipitation, notably chromium carbides in stainless steels, is a well
> recognized and accepted mechanism of weld decay. In this case, the
> precipitation of chromium carbides is induced by the welding operation when
> the heat affected zone (
HAZ) experiences a particular temperature range
> (550oC~850oC). The precipitation of chromium carbides consumed the alloying
> element - chromium from a narrow band along the grain boundary and this
> makes the zone anodic to the unaffected grains. The chromium depleted zone
> becomes the preferential path for corrosion attack or crack propagation if
> under tensile stress.
>
> Prevention - Weld decay can be prevented through:
>
> * Use low carbon (e.g. 304L, 316L) grade of stainless steels
> * Use stabilized grades alloyed with titanium (for example type 321) or
> niobium (for example type 347). Titanium and niobium are strong carbide-
> formers. They react with the carbon to form the corresponding carbides
> thereby preventing chromium depletion.
> * Use post-weld heat treatment.
>
> ______________________
> Here is an article that might help
>
> http://www.journalarchive.jst.go.jp/jnlpdf.php?cdjournal=isijinternational19
> 66&cdvol=25&noissue=5&startpage=418&lang=en&from=jnlabstract
>
> Best Regards,
>
> Richard M. Beldyk PhD, PE, CWEng
>
> Supervisor Quality Engineering
> Alstom Power, Inc.
>
Chattanooga, TN USA
>
> Original Message:
> -----------------
> From: saqib jalal sakib321@gmail.com
> Date:
Tue, 22 Dec 2009 08:01:50 +0500
> To:
materials-welding@googlegroups.com
> Subject: [MW:3870] root cause anaylsis
>
>
> dear all
> i want to discuss one case study with you i am working in a chemical plant
> and one of our plant is Nitric acid production in it on of our equipment is
> stationary ( BLEACHING TOWER) whose function is to absorb oxides of nitrogen
> from 50-60 nitric acid at average 70-90 centigrade by spraying water from
> top and moving up the nitric acid from bottom. the main problem is that the
> material of this tower is ss 321 and in shut down we observe severe
> depletion in the thickness of shell especially near the
HAZ of welds so
> would you please tell me most probable cause of this failure and its most
> possible remedy
>
> --
> with Regards
>
>
> SAQIB JALAL
> Inspection Engineer
> PakArab Fertilizer Limited
> Khanewal Road ,
Multan
> office number +92-61-9061 EXT 3110
> mobile number +92-321-4043556
>
>
>
> --
> with Regards
>
>
> SAQIB JALAL
> Inspection Engineer
> PakArab Fertilizer Limited
> Khanewal Road ,
Multan
> office number +92-61-9061 EXT 3110
> mobile number +92-321-4043556
>
> --
> To post to this group, send email to
materials-welding@googlegroups.com
> To unsubscribe from this group, send email to
> materials-welding-unsubscribe@googlegroups.com
> For more options, visit this group's bolg at
> http://materials-welding.blogspot.com/
> The views expressed/exchnaged in this group are members personel views and
> meant for educational purposes only, Users must take their own decisions
> w.r.t. applicable code/standard/contract documents.
>
>
> --------------------------------------------------------------------
> mail2web.com – What can On Demand Business Solutions do for you?
> http://link.mail2web.com/Business/SharePoint
>
>
> --
> To post to this group, send email to
materials-welding@googlegroups.com
> To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
> For more options, visit this group's bolg at http://materials-welding.blogspot.com/
> The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



THIS MESSAGE IS ONLY INTENDED FOR THE USE OF THE INTENDED RECIPIENT(S) AND MAY CONTAIN INFORMATION THAT IS PRIVILEGED, PROPRIETARY AND/OR CONFIDENTIAL. If you are not the intended recipient, you are hereby notified that any review, retransmission, dissemination, distribution, copying, conversion to hard copy or other use of this communication is strictly prohibited. If you are not the intended recipient and have received this message in error, please notify me by return e-mail and delete this message from your system. Ontario Power Generation Inc.

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...