Monday, December 14, 2009

[MW:3829] RE: 3826] RT Requirments

I assumed, code of const. is B 31.3.
As far as B 31.3 code is concern, Extent of RT check is not required to change. Please refer relevant Para. 3414.4.1 (4), 345.1(b), (c), 345.5.
For the Pneumatic test, stored energy calculation may be required in accordance with ASME PCC-2, Article 5.1, Appendix II.
 
For the utilities lines (Instrument Air) - 10% RT is sufficient. but Extension of RT may be increased if your rating (Design pressure) is ≥ 600#.
Recently  I came across one of the Client spec (Total Exploration & Production) where it is indicated that "100% RT for lines subjected to Pneumatic Test" for the hydro carbon and cryogenic Services.
 
Regds/Jignesh


From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of P. PALANIVEL
Sent: Monday, December 14, 2009 9:17 AM
To: materials-welding@googlegroups.com; arulvijiya@gmail.com; p.arul@cairnindia.com
Subject: [MW:3826] RT Requirments

Dear Friends Good DAY,
 
Can any one help for the below quiery,
 
A requirement for to replace Pnuematic test in palce of Hydro test for Instrument Air line.  Already there is a requirment of 10% Radiography of the line. What will be the RT required % if Pnumetaic test is carried out.
 
Pl. also let us know where may the requirment is given in CODEs or any other Project spec.
 
 

Thanks & Regards,

 

Palanivel.P

Quality Superintendent.

CAIRN INDIA,

Barmer, Rajasthan - 344 001. India.

Mobile   :   +91 90018 94547 & +91 97904 00797.

E Mail    :    p.palanivel@cairnindia.com

                     www.cairnindia.com

 

 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...