Dear all,
Please refer to attached stress -strain graph obtained during tensile testing of SA 106 Gr B pipe.
While performing tensile testing of SA 106 pipes for Div 1 vessels ,we were not getting yield point even though required tensile strength is obtained.
The specimen were taken in both transverse and longitudinal direction from half thickness.
Kindly share your experience in finding the root cause..
Please inform if any further details is required for clarity.
Best regards,
Padmasanker,
Quality coordinator,
Bilfal heavy industries ltd.
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
Visit this group at http://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAKDH8Gq%2BubEPKfFeaLTemr8ekcAO-KuOaddmKfrjwLEoDahXYQ%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.