Friday, November 30, 2012

Re: [MW:16094] PWHT for blind flange

PWHT for blind flange to nozzle neck (Category-D joint) is mandatory, also ASME name plate shall be stamped as PHT.
 
Regards
Sudhir Kumar

On Thu, Nov 29, 2012 at 10:28 PM, Vicky Patil <patilvicky4@gmail.com> wrote:
Dear expert,

Vessel  PWHT Not required, But Main Nozzle having blind flange & its thickness above 40 mm also one nozzle attached with set through joint welded on Center Blind Flange.

My question is after welding we done SR for Blind Flange or Not?

Regards,
Chetan 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

No comments:

[MW:35504] Re: Clarification on SS304 Pipe EFW and RF Pad Weld Alignment per ASME Standards

Dear Experts, I am following up on my earlier emails regarding the alignment of weld seams on SS304 pipes and their reinforcing pads (RF p...