Monday, November 26, 2012

Re: [MW:16050] welding with EL8

No (Due To difference in Mn %)

Regards

Hiren Sevak

On Mon, Nov 26, 2012 at 2:24 PM, kiran kumar <chvvn.kirankumar@gmail.com> wrote:
Dear Sir
 
Can we weld with Filler wire  EL8 with supporting PQR  EH 14 Filler wire (having same F no:6)
 Material IS 2062
 Construction code -BPVC Section IX
 Process-SAW Process.
 
Thanking you
 
CH.V.V.N.KIRANKUMAR
 
+91 7898905072
 
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

No comments:

[MW:34820] RE: 34813] Clarification in Rate of heating and cooling.

Hello,   Please see the response below.   Regards.   P. Goswami, P. Eng, IWE.   From: materials-welding@googlegroups.com <materials-weld...