Thursday, November 22, 2012

Re: [MW:15999] WQT without WPS

All welds shall be rejected. RT/UT & hydrostatic test are not substitute for such non-conformities.  Any construction code for any type of welds, welding procedure is mandatory.
NDE does not confirm or guarantee the integrity of weld joints. Hydrostatic test does confirm the mechanical properties of Welds as hydro test pressure will be lesser than yield & tensile strength.
Regards

On Wed, Nov 21, 2012 at 11:18 PM, Sudhir Kumar <sudhir18092@gmail.com> wrote:


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...