Dear Sir, It seems the weld defect is due to i) Welder skill if it is ok ii) Flux coating of the Electrodes Why not change the brand and try As such these typeE8018B2L of elctrodes are being used by many fabricators w/o problems Please check Current, Voltage and bead placement and also Joint configuration Regards Hegde
--- On Fri, 30/11/12, sudalai kannan <sudalaims@gmail.com> wrote:
From: sudalai kannan <sudalaims@gmail.com> Subject: Re: [MW:16091] Consumable for SA 387 GR-12.CL2 materials To: materials-welding@googlegroups.com Date: Friday, 30 November, 2012, 3:31 PM
Dear sir,
The base material is SA 387 GR12.CL2 it's conformed, we tried with E8018-B2 (ESAB), but the Radiographic reports shown on everywhere is Incomplete fusion, We follow proper Preheat, Interpass & we used the good welder for the joint.
Then only client informed us to use E7018-B2L electrode.
Please give me feed back the above issue.
Thanks to you.
Regards, M.Sudalai. On 30 November 2012 08:56, HAREESH K V <hareesh13h@gmail.com> wrote: Dear Sir,
You can use E7018-B2L of E8018-B2L. Not got a good result? What happened, please explain.
Regards,
Hareesh K V +8306703707 -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com For more options, visit this group's bolg at http://materials-welding.blogspot.com/http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
|
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/ http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
No comments:
Post a Comment