Can some body give opinion on below case of closer welds.
How can we accept above situation with resepct to any technical justification (PTC etc...)!
Material - P. No. 5A - (SA 387 Gr 22 )
Service - Hydorgen
Thickness - 45 mm
Design code ASME Sec VIII Div I & API 934 A
-- To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.