If the material required is SA 516 Gr 70 N and the material received
is completely satisfying the requirement but the marking observed on
plate is without "N" or "MT". Can we accept the material for Code
stamped vessel??
My interpretation of the code requirement is,
As per SA 516 Para 13.1.2, marking should include MT also.
Please advice whether MT is inclusive of Normalizing.
Regards
Akhil
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.