Process: WPS qualification for SMAW through thickness double repair
Electrodes: root pass E-7018, HT, fill and cap E-7018-1
Code: API 1104
Pipe Diameter PQR: 24"
ISSUE: 2 of 4 specimens failed on Nick break test showing porosity and slag.
My questions:
1.- Can I support with only 2 passed test that the WPS is approved?
2.- Why codes ask for soundness tests like bend and nick break for WPS qualification?, I mean we would just need to test mechamical properties like tensile, hardness, charpy, etc
3.- It is a fact that the cause the test failed was because welder workmanship not the pocess is bad
Thanks for help me.
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.