Greeting,

Do not confuse with all the tables you have. Refer only the table which are applicable to your job by code of constructions are as detailed out in the procedure.

Refer to your procedure or code of constriction (as some code required to add reinforcement when you selecting the IQI)

Different code have different Tables.. Generally all are follow the 2% sensitivity requirement in case of wire type IQI and 2-2T in case of plaque type IQI.

 

For selecting the wire or plate type IQI first calculate the 2% (if sensitivity requirement is 2%) of the job thickness under testing. Refer that number in the table which will give you the value for the designated required wire or plate type IQI and the wire set in which the wire include.(many time you will not find exact no so select the smallest wire diameter wire available to your calculated values)

 

Still you have some doubt send me your joint details and code/specification applicable .I can help you selecting the wire.

Better get the technique sheet write and approved by level-iii/experienced people where you will find all the relevant information.

Regards, Bhaskar kale

bmkale@gmail.com

 


On Mon, Dec 27, 2010 at 1:26 AM, Ahmed Elias <alyassahmed@gmail.com> wrote:
Thanks Gamne Krishnar,
 
        My question was not clear  there's any formula(relation between the wall thickness and wire diameter) because I have many table(see the attached file) similar to your table.
 
 Thanks for your help


 
On Sun, Dec 26, 2010 at 11:09 AM, Kisan Gamane <kisankrishna1506@gmail.com> wrote:
Dear Ahmed
Pls. find attached details which will helps to u.
 
Thanks & regards
 
Gamne Krishna
Nasik India
 


 
On Sat, Dec 25, 2010 at 6:21 PM, ahmed muhammad <alyassahmed@gmail.com> wrote:
Dear All,
   I need the way to slect the IQI for radiographic film

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



--

किसन गामणे

नाशिक

जन्मलो म्हणून जगणार नाही
अन असाच राखेत विरणार नाही...
ठसे सोडूनी जाईन जीवन काठावरती
आल्या लाटा कितीही , मिटणार नाही ...

 

खुभी नाही माझ्यात एवढी  कि..!
कुणाच्या  हृदयात ठाण  मांडून  जाईल..!
पण विसरणे सुद्धा अशक्य होईल..!
असे  क्षण  देऊन जाईल.......!

 


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



--
 
 
AHMED MUHAMMAD ELIAS
MECHANICAL ENGINEER
ASNT LEVEL II NDT INSPECTOR 
IRAQ :-+9647710951885,+9647503136603
PLEAS FEEL FREE TO CONTACT ME FOR ANY INQUIRY

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.



--
धन्यवाद,
भास्कर मनोहर काळे
+60149129098

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

Comments

Popular posts from this blog

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

[MW:5202] RE: 5200] NDT after PWHT

------------------------------------- Interpretation:  I‑89‑14 Subject:         Section I (1986 Edition, 1987 Addenda), PW‑11,                  NDE Prior to PWHT Date Issued:     December 15, 1988 File:            BC88‑393   Question: Does PW‑11 require that NDE be performed on welds after they have been subjected to the postweld heat treatment required by PW‑39?   Reply: No, unless the conditions described in PW‑11.2.2 exist. ---------------------------------------------- Interpretation:  VIII-1-98-09 Subject:         Section VIII, Division 1 (1995 Edition, 1996 Addenda); NDE                 ...

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...