Dear Jignesh, when electrode is manufacured, if the cake ( wet flux) is not concentic to core wire, this problem is possible.Hence you get problem like taper buring.Problem is weld- is porosity . Better to replace. Regards, Manish Kulkarni
--- On Wed, 29/12/10, Jignesh Desai <jignesh.desai.met@gmail.com> wrote:
From: Jignesh Desai <jignesh.desai.met@gmail.com> Subject: [MW:8989] E -7018 (TAPPER BURNING) To: materials-welding@googlegroups.com Date: Wednesday, 29 December, 2010, 8:33 PM
Can anybody write some technical reasons behind tapper burning of subject electrodes with high fluctuations of current and wastage of excessive stub length because of red hot (@ 30%)? Also with above, what could be the possible defects in the weld joints? Regds/Jignesh -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com For more options, visit this group's bolg at http://materials-welding.blogspot.com/The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
|
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at
http://materials-welding.blogspot.com/ The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.