Wednesday, December 29, 2010

[MW:8980] ELECTRODE QUALIFICATION TEST

Dear All,
We need to fabricate a piping with carbon steel and low
alloy steel welding electrode section i saw one project 6010 for root
alternate passes 7010.But both cellulose electrodes(high hydrogen
content)may be chances there hydrogen cracking please give ELECTRODE
QUALIFICATION TEST details(as per ASTM standard)


Regards,
Devendar G

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...