Thursday, December 30, 2010

[MW:9004] Re: ER Ni Cr Mo-3 WELD OVERLAY

Dear Rinshu,

Please note that in the Inconel Weldoverlay(ER Ni Cr Mo-3). There is
restriction of Fe not Ferrite.

Most of the time Fe is restricted to maximum 5%.

You are getting Fe 0% is good because most of the time welding
engineer is struggling to maintain Fe below 5%

Best Regards,

JASPAL SINGH CWI-AWS, CSWIP-3.1
ISGEC-PED, Yamunanagar, Haryana (India) PH: +911732307251 ; Mob.
+918930111441(CUG), +919996624244


On Dec 29, 11:45 pm, rinshu <rinshad...@gmail.com> wrote:
> Dear all
>
> we have done CRO on SA516 Gr.70 ,we got ferrite content above 2.5mm
> from the weld interface as 0% will it have any negative effect on our
> CRO(ER NiCrMo-3-filler,SAW-process)

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.