Friday, December 24, 2010

RE: [MW:8917] Problem of PWHT

Generally Impulse lines are outside scope of ASME B31.3 and don't require PWHT. Even if it is designed by B31.3 it doesn't require PWHT as thicknesses low, , unless it is a contractual requirement

-----Original Message-----
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of vivek m
Sent: Thursday, December 23, 2010 9:34 PM
To: materials-welding@googlegroups.com
Subject: [MW:8914] Problem of PWHT

Dear all,
one of my P11 impulse pipe (0.75") is connected to a CS 0.75" valve
which comes with big bore CS line (all as per drawing)......now shall
i do pwht to that joint ? If done will there be any problem to that
joint ...please give me a detailed answer.


Filtered by Hosted Filtering


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...