Monday, December 27, 2010

[MW:8961] T K Y WELDER QUALFICATION

Hi,

 

If anybody is having T K Y Welder qualification as per AWS D1.1 Fig 4.27,

 

With SMAW - Root and Hot pass / FCAW -FILL and Cap.

 

Thickness used = 12.7mm, Diameter 8”

 

Please let me know, what will be thickness range for SMAW and FCAW.

 

My interpretation based on the Table 4.11, SMAW+FCAW = 5mm to unlimited.

 

 

With Kind regards,

 

S.Elumalai.

No comments:

[MW:35597] INCONEL 825

Dear all  INCONEL 825 matching filler   ER NI FECR-1 its correct please guide me Regarding  Elavarasan -- https://materials-weldin...