Technical details regarding backing weld shall be availed from AWS D 1.1
Regards
R.Venkataraman
Date: Sat, 28 Feb 2009 10:56:43 +0400
Subject: [MW:1663] Buttering on Plate
From: pkhormis@gmail.com
To: materials-welding@googlegroups.com
Dear All!!!
We are doing some Tanks as per API 650. In one of that tank ,we faced a problem like shortened the lingth of plate..and JOINT GAP became more than the required 'Root gap'. Almost "55mm" we got .So we thought about 'Buttering'. But in API 650 not mentioned any thing about 'buttering'. So which standard we have to follow for it, and what are the test we have to conduct over there.
There was no PWHT as per WPS,Pre heat was only upto 40 ^0 C.
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---