Re: [MW:30820] Low Hydrogen Electrode not using in Under ground pipeline laying

Dear Harish Varude 


      As per the API 1104 (Welding of pipelines and related facilities) clause 4.2.2.1 & 5.4.2.7 is addressing the usage of low hydrogen electrode so you can use LHE for underground pipelines.LHE were developed for welding low-alloy, high-strength steels.
Regards
Madhusoodhanan Nair.G
Sr Manager (Operations)
VCS Quality Services Pvt Ltd
Mob- +917977762694,+919967901872 

On Tue, Apr 28, 2020 at 9:13 AM HARISH VARUDE <harish.varude02@gmail.com> wrote:
Dear all,

Can we use low Hydrogen Electrode in under ground pipeline works.??
If yes , please let me know standards and clause.

From
Herish

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAGP-YKK3Do52gdMLiUL9Ub%2BbRXBGz3%3DmLZYd_W7wJeEjh3Q61Q%40mail.gmail.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAE12Qq6NdePBp4OZpY5atx2ni_zuaECYbo3T4J9KM2yEHYjU0Q%40mail.gmail.com.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...