tnx for your reply
-- So its mean that i should prepare two different Test coupon or what
and for the maximum thikness of base metal from QW 451.1 THEY MENTION THAT T QUALIFIED X 2 ITS MEAN 7.92 X2 = 15.84 mm
Le mercredi 8 avril 2020 13:52:38 UTC+2, gerr...@yahoo.com a écrit :
Considering Pipeline, API 1104 code was considered for below.1. One PQR for X60 material2. Another PQR for X65 material to be qualified'If you qualify PQR on 6 inch wall thickness 7.92 mm then it qualifies from wall thickness 4.8mm to 19.1mm and no Limitation on DiameterThanks & Regards
J.Gerald Jayakumar
On Wednesday, April 8, 2020, 03:10:03 PM GMT+7, QA/QC <adnan...@gmail.com> wrote:Hello--i want to prepare a WPS for pipeline work with base metal API 5L X60 - X65 SMAWfor the test coupon i want to use 6" with thickness = 7.92 mmwant to know the minimum and maximum range for size and thickness used for the PQRBEST REGARDS
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to material...@googlegroups.com .
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/ .0230b3b5-7871-4efa-94d7- 609f4effa70a%40googlegroups. com
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/94cc40bc-2a64-4a7c-828d-034cc090d77b%40googlegroups.com.
No comments:
Post a Comment