Skip to main content

Re: [MW:30775] Thermowell Material , Metal Dusting, downstream of Hydrogen reformer

Subject changed, pl reply only to this thread

On Wednesday, April 15, 2020 at 10:50:12 AM UTC+5:30, ATUL KHATRI wrote:
Hi Hernan,
Could you please give some more details ?
What is the temperature of your reformed gas ?
Are you sure it's because of metal dusting ?
What does your licencor says ?


Hope I can help you after your replies . 

Br,
Atul 


On Wed, Apr 15, 2020 at 9:19 AM Hernan Arturo Castillo Mier <Hernan.Castillo@ecopetrol.com.co> wrote:

We have metal dusting corrosion in two thermowells, downstream of Hydrogen reformer.

Any have experience about this problem?

Thermowells are Incolloy 800HT.  This is not the best metallurgy for this corrosion problem.

According to NACE, the better metallurgy is Alloy 699 XA.

We are looking for any factory that  produce thermowells using that metallurgy.

 

Thanks,

 

 

Hernán Castillo Mier

Senior Engineer

Reliability and integrity of Static equipments.

API 510 (33119)

Ecopetrol   Cartagena Refinery

 

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/6f0c7c27-2cd1-4964-b05b-763d114f5b5f%40googlegroups.com.

Comments

Popular posts from this blog

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

[MW:5202] RE: 5200] NDT after PWHT

------------------------------------- Interpretation:  I‑89‑14 Subject:         Section I (1986 Edition, 1987 Addenda), PW‑11,                  NDE Prior to PWHT Date Issued:     December 15, 1988 File:            BC88‑393   Question: Does PW‑11 require that NDE be performed on welds after they have been subjected to the postweld heat treatment required by PW‑39?   Reply: No, unless the conditions described in PW‑11.2.2 exist. ---------------------------------------------- Interpretation:  VIII-1-98-09 Subject:         Section VIII, Division 1 (1995 Edition, 1996 Addenda); NDE                 ...

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...