Hi,
Check this general precautions and correction practice.
https://www.twi-global.com/technical-knowledge/job-knowledge/distortion-corrective-techniques-037
Regards,
MOHAMED MUNEEB MAHABOOB
''If you know any art by any means then
SCULPT IT - no matter how cheap or
useless it is - JUST SCULPT IT,
you will never know when experts will
be on demand''
--Dear All,For a storage tank as per API 650 construction (Dia- 60 mtr, height- 14.3 mtr), the external floating roof (Single deck) has been found with some buckling, waviness & gap between the leg support and deck pipe sleeve not maintained as per the drawings. I have referred Appendix C of API 650, not recommended acceptance criteria for waviness, buckling of decks and leg support gaps. Kindly share your experience on this above subject (Attached some snaps).Ramachandran.MTank EngineerWood.Kuwait