Sunday, November 26, 2017

Re: [MW:27060] TORQUE VALUE

Dear Ari,
Please can you send me the BOLT TORQUE LOADS TABLE you send to Javed?

Regards,
Daniel

On Sunday, August 2, 2009 at 2:25:23 PM UTC+1, Ari wrote:
Dear Javed, Enclosed the details,
 
Regards,
 
Nom. Fig.

Size

Ins. (mm)

Bolting

No. x Dia.

Ins.

Rec.

Bolt Stress

lb/in2

Torque lbf.ft. (Nm)

Bolt Lubricant

Molykote 1000 (ยต = 0.11)

36                     (900)

20         x          3 ½"      UN8

45,000

15983

(21670)



On 8/2/09, Mohammad Javeed <mmubash...@gmail.com> wrote:

Dear all

Have a nice day

I need your help about one query regarding torque value. We have a one flange joint of dia  36" RF CL. 900 material A350-LF2.and bolt length is 800mm. As per our client requirement this tightening should be done with hydraulic tensioning system. So what should be the torque value for this flange?

 

Thanks

M javed   


--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.

No comments:

[MW:34920] Tubesheet Hole step

Hello Team, I have one question any tolerance given for tubesheet Hole step. Please do needful. Regards, AP  -- https://materials-...