hi
Dear sir
with ref. to your message please be informed that with my opinion if the pressure
test to be between 20@80% of dial gauge is accepted.Meanwhile chart is accepted.
best regards
h.sarpasi
On Monday, November 6, 2017 09:08:37 AM IRST, Babu Kathalingam <kbabupsg@gmail.com> wrote:
Gents
Some one has expereicne of using the different range chart with guage range i.e .
Both Gauge /chart ranges are calibrated for 0 ~20000 psi , however if we use 0~10000 psi chart with the 0~20000 psi guage , will make any differnce compared with use of both 0 ~20000 psi range ?
Thanks & regards,
Babu
Babu
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.
No comments: